FDAClass II · Medical device · Recall Z-0161-2027 · Recalled October 21, 2026
IQ200 SPRINT recall — Beckman Coulter, Inc.
Agency report date: October 21, 2026.
1. Compare your item
This notice names a product; your particular item is not yet verified. Compare every applicable model, serial, lot, production-date or model-year boundary below.
Agency product description and boundaries
IQ200 SPRINT, REF: 700-3322,700-3322RFB, 700-3325, 700-3326, B48997; IQ200 SELECT, REF: 700-3340, 700-3345, 700-3347, B48998, C10684; IQ200 ELITE, REF: 700-3370, 700-3375, 700-3375RFB, 700-3376, B48999, C10683
Still to verify: match the label on your item with the full official notice, including any exclusions, tables and photos. Some identifiers appear only on the agency website and are absent from this data feed. A missing field does not mean all versions are affected.
If your lot or date falls outside a stated range, this notice has not established that your item is affected. This is not a finding about other recalls or product safety.
2. Agency hazard and consumer action
FDA reports: The rinse-line check valve has a shorter service lifespan than originally expected and requires annual replacement to prevent lamina fluid leakage; however, the check valve replacement was excluded from the annual preventive maintenance (PM) requirements without adequate reliability evaluation. When the check valve is not replaced annually, it may allow lamina fluid to migrate internally and leak onto the table or floor, potentially resulting in exposure to physical hazards (slip/fall), chemical hazards (lamina fluid exposure), biohazardous exposure, property damage, and delayed patient results.
No consumer remedy instructions are supplied in this record. Check the official notice and listed company contact for the agency’s current instructions.
Class II: may cause temporary or medically reversible health consequences.
Affected product: IQ200 SPRINT recall status
3. Open the official notice or contact
View the official FDA enforcement record (openFDA) ↗
Affected products
Companies & origin
Identifying details (verbatim from the notice)
Related recalls
More Beckman Coulter recalls
- ROTOR ASSY-SW41 recall — Beckman Coulter, Inc.FDA · October 28, 2026
- ROTOR ASSY-SW40 recall — Beckman Coulter, Inc.FDA · October 28, 2026
- DxU 840m Iris recall — Beckman Coulter, Inc.FDA · October 21, 2026
- DxC 500 AU Clinical Chemistry Analyzers recall — Beckman Coulter Inc.FDA · October 14, 2026
- DxC 500i Clinical Analyzer Modules recall — Beckman Coulter Inc.FDA · October 14, 2026
Other medical device recalls from around the same time
- VOCSN+Pro (Japan) recall — Ventec Life Systems, Inc.FDA · October 28, 2026
- VOCSN+Pro recall — Ventec Life Systems, Inc.FDA · October 28, 2026
- The ABL90 FLEX and ABL90 FLEX PLUS analyzers are intended for use by trained technologists recall — Radiometer Medical ApSFDA · October 21, 2026
- Medline convenience kit labeled as recall — Medline Industries, LPFDA · October 21, 2026
- Vinyl Instrument Guards recall — Healthmark Industries Co., Inc.FDA · October 21, 2026
- CPSC — consumer products ↗ (aggregated here)
- NHTSA — vehicles, car seats, tires ↗ (aggregated here; use NHTSA's VIN lookup to check a specific vehicle)
- FDA — food, drugs, medical devices ↗ (aggregated here)
- USDA FSIS — meat, poultry & processed egg products ↗ (not aggregated here)
- Recalls.gov — the U.S. government’s all-agency portal ↗
Found something wrong or missing? Report a data error.
Source: U.S. Food & Drug Administration. Agency excerpts come from the public data feed and may omit tables or later changes; the linked government source is authoritative. Source last checked November 25, 2026 at 6:00 AM UTC. Record retrieved November 25, 2026 at 6:00 AM UTC.