FDAClass II · Medical device · Recall Z-3253-2026 · Recalled September 30, 2026

nGenuity Patient Monitor with Capnography (ETCO2) CAT 8100E1-ST-US recall — Criticare Technologies, Inc.

Agency report date: September 30, 2026.

1. Compare your item

This notice names a product; your particular item is not yet verified. Compare every applicable model, serial, lot, production-date or model-year boundary below.

Product named
nGenuity Patient Monitor with Capnography (ETCO2) CAT 8100E1-ST-US
Company / brand
Criticare Technologies
Lot / serial / date codes
UDI-DI +B4388100EP1US02 All units with CO2 option SN beginning with 424, 125, 225, 325, 425, 126, 226, 326, 426, date range 2024-1st qt 2026
Distribution
US Nationwide distribution including in the states and territory of AL, AZ, CA, CO, CT, DE, FL, GA, HI, IA, ID, IL, IN, KY, LA, MA, MD, ME, MI, MN, MO, MT, NC, ND, NH, NJ, NV, NY, OH, PA, RI, SC, SD, TN, TX, UT, VA, VT, WA, WI, and Puerto Rico.
Agency product description and boundaries

nGenuity Patient Monitor with Capnography (ETCO2) CAT 8100E1-ST-US, CAT 8100E1-US, CAT 8100EP1, CAT 8100EP1-ST, CAT 8100EP1-ST-US, CAT 8100EP1-US, CAT 8100EP1R

Still to verify: match the label on your item with the full official notice, including any exclusions, tables and photos. Some identifiers appear only on the agency website and are absent from this data feed. A missing field does not mean all versions are affected.

If your lot or date falls outside a stated range, this notice has not established that your item is affected. This is not a finding about other recalls or product safety.

2. Agency hazard and consumer action

FDA reports: Complaint trend where "Checkline Error" alarm presents at device setup, rendering the CO2 monitoring function inoperable. May result in procedure delay.

No consumer remedy instructions are supplied in this record. Check the official notice and listed company contact for the agency’s current instructions.

Class II: may cause temporary or medically reversible health consequences.

Affected product: nGenuity Patient Monitor with Capnography (ETCO2) CAT 8100E1-ST-US recall status

3. Open the official notice or contact

Official recall ID
Z-3253-2026
Brand
All Criticare Technologies recalls
Classification
Class II
Units affected
1,007
Recall status
Ongoing
Initiated
Voluntary: Firm initiated

Affected products

Companies & origin

Recalling firm location
Warwick, RI, United States
Firm address
333 Strawberry Field Rd Ste 11, 02886-2459

Identifying details (verbatim from the notice)

Product codes / lots
UDI-DI +B4388100EP1US02 All units with CO2 option SN beginning with 424, 125, 225, 325, 425, 126, 226, 326, 426, date range 2024-1st qt 2026
Distribution
US Nationwide distribution including in the states and territory of AL, AZ, CA, CO, CT, DE, FL, GA, HI, IA, ID, IL, IN, KY, LA, MA, MD, ME, MI, MN, MO, MT, NC, ND, NH, NJ, NV, NY, OH, PA, RI, SC, SD, TN, TX, UT, VA, VT, WA, WI, and Puerto Rico.
Firm notified the public via
Letter
FDA event ID
99545
Recall initiated
May 6, 2026
FDA classified
September 22, 2026
FDA report date
September 30, 2026