FDAClass I · Medical device · Recall Z-3132-2026 · Recalled September 23, 2026
StatStrip Glucose and B- Ketone meter recall — Nova Biomedical Corporation
Agency report date: September 23, 2026.
1. Compare your item
This notice names a product; your particular item is not yet verified. Compare every applicable model, serial, lot, production-date or model-year boundary below.
Agency product description and boundaries
StatStrip Glucose and B- Ketone meter. Model No: 66429. Glucose test system.
Still to verify: match the label on your item with the full official notice, including any exclusions, tables and photos. Some identifiers appear only on the agency website and are absent from this data feed. A missing field does not mean all versions are affected.
If your lot or date falls outside a stated range, this notice has not established that your item is affected. This is not a finding about other recalls or product safety.
2. Agency hazard and consumer action
FDA reports: A software synchronization/timing issue in the barcode scanning and patient data processing component that causes the device to intermittently retain a previously scanned barcode including patient identification (ID) barcodes and quality control (QC) solution ID barcodes when a new barcode is scanned, resulting in the prior barcode information remaining displayed on the screen for the current test. When this defect occurs and the operator accepts the incorrectly displayed patient information without recognizing the mismatch, the current patient's glucose result will be incorrectly assigned to the previous patient's medical record and transmitted to the data management system (DMS), and the current patient's medical record will not receive a result, leaving their glucose status unrecorded and their clinical management without the information needed to guide treatment decisions. The previous patient, whose medical record now contains a glucose result that does not belong to them, may receive inappropriate clinical intervention based on that erroneous result, particularly in critically ill patients, neonates, and infants who cannot communicate symptoms or self-treat. The defect also affects QC barcode scanning: if a QC scan triggers the same retention behavior, QC results may be attributed to an incorrect identifier or QC tests may fail without the user recognizing the underlying cause. This defect does not affect the analytical accuracy of glucose measurements.
No consumer remedy instructions are supplied in this record. Check the official notice and listed company contact for the agency’s current instructions.
Class I: most serious — reasonable probability of serious health consequences or death.
Affected product: StatStrip Glucose and B- Ketone meter recall status
3. Open the official notice or contact
View the official FDA enforcement record (openFDA) ↗
Affected products
Companies & origin
Identifying details (verbatim from the notice)
Related recalls
More Nova Biomedical recalls
- StatStrip Glucose and B- Ketone meter recall — Nova Biomedical CorporationFDA · September 23, 2026
- StatStrip Glucose and B- Ketone meter recall — Nova Biomedical CorporationFDA · September 23, 2026
- StatStrip Glucose Hospital Meter System recall — Nova Biomedical CorporationFDA · September 23, 2026
- StatStrip Glucose Hospital Meter System recall — Nova Biomedical CorporationFDA · September 23, 2026
Other medical device recalls from around the same time
- INCA (Infant Nasal Cannulae Assy) Neonatal Nasal CPAP recall — CooperSurgical, Inc.FDA · September 30, 2026
- INCA (Infant Nasal Cannulae Assy) Infant Nasal CPAP recall — CooperSurgical, Inc.FDA · September 30, 2026
- Haylard UNIV IMAGING BIOPSY TRUCUSTOM recall — AVID Medical, Inc.FDA · September 23, 2026
- Haylard BASIC BIOPSY TRAY recall — AVID Medical, Inc.FDA · September 23, 2026
- Haylard CONTINUOUS NERVE BLOCK TRAY recall — AVID Medical, Inc.FDA · September 23, 2026
- CPSC — consumer products ↗ (aggregated here)
- NHTSA — vehicles, car seats, tires ↗ (aggregated here; use NHTSA's VIN lookup to check a specific vehicle)
- FDA — food, drugs, medical devices ↗ (aggregated here)
- USDA FSIS — meat, poultry & processed egg products ↗ (not aggregated here)
- Recalls.gov — the U.S. government’s all-agency portal ↗
Found something wrong or missing? Report a data error.
Source: U.S. Food & Drug Administration. Agency excerpts come from the public data feed and may omit tables or later changes; the linked government source is authoritative. Source last checked October 22, 2026 at 6:00 PM UTC. Record retrieved October 22, 2026 at 6:00 PM UTC.